PRODUCT PARAMETERS

Synchronous Chip Sealer Truck 23m³ SHACMAN

project Descriptions Specifications
Body Asphalt Tank Capacity 8,000
Chip Hopper Capacity 15,000
Tank material Stainless Steel
Control system PLC control system
Insulation Thickness 100mm(Configurable upon request)
Asphalt Agitation Method Combined auger and paddle agitation
Auxiliary Engine Optional
Spraying Width ≤4.5m
Spraying Accuracy 1%
Aggregate Spread Rate 2-22 L/㎡
Application Rate Range 0.2–2 kg/m²
Aggregate Chip Size 3-25 mm
Heating System 2 burners + full-circuit heat transfer oil circulation heating
Chassis

 

Chassis brand SHACMAN
Drive form 8*4
Engine brand and model Multiple engine options available.
Max engine power(Kw) 275
Engine emission standard Matched to destination country regulations
Gearbox Fast 12 speed forward 1 reverse
Front/rear axle(t) 7.5/16

VEHICLE ADVANTAGES

INTELLIGENT AND PRECISE SPREADING SYSTEM

Asphalt Tank Insulation Structure for Synchronous Chip Sealer

The insulation and protection system of the asphalt tank consists of four layers from inside to outside: tank body, multi-layer insulation blanket, metal support framework, and white stainless steel outer shell. It minimizes heat loss during heating, transport, and on-site waiting.

  1. Multi-layer insulation to minimize heat loss
    The tank exterior is covered with multi-layer rock wool (or glass wool) insulation boards, featuring low thermal conductivity, high-temperature resistance, and non-combustibility. With asphalt typically at 140–280 °C, the insulation layer minimizes heat dissipation and ensures slow temperature drop during long-distance relocation and on-site waiting.

  2. Staggered layered installation to eliminate thermal bridges
    Insulation boards are installed in staggered joints by zone, with seams not aligned at the same position, reducing through-gaps that form thermal bridges. Penetration points such as pipe connections and flanges are individually reinforced with insulation to prevent localized rapid heat loss.

  3. Metal support framework to prevent sagging and detachment
    A metal mesh and support strip framework outside the insulation layer firmly compresses the insulation boards against the tank wall. The structure does not sag, crack, or detach under prolonged vibration and bumping, and insulation performance does not degrade over time.

  4. Stainless steel outer shell for protection and appearance
    The outermost layer is a white stainless steel outer shell covering the entire tank body and both end heads. It protects the insulation layer from rainwater, dust, and chip impact, preventing moisture absorption and sudden insulation performance drop, while providing a clean, durable, and easy-to-clean appearance suitable for export and high-end project presentation.

  5. Fuel savings and reduced operating cost
    Good insulation performance means the burner requires less heat to maintain temperature, shortening heating time and reducing ignition frequency, directly lowering diesel consumption and operating costs—the most tangible long-term benefit for customers.

  6. Stable temperature to ensure construction quality
    Small asphalt temperature fluctuations ensure stable viscosity, making it easier to control the application rate at the set value. The spray fan pattern remains uniform, avoiding poor atomization and pipe blockage caused by sudden temperature drops.

  7. Enhanced insulation at end heads
    The end heads of the tank account for a large proportion of heat dissipation area. Insulation and framework are densely arranged and fully wrapped at these locations to reduce uneven temperature caused by “cold ends.”

Core Functions of the Asphalt Agitation System

  1. Prevent segregation and settling
    Continuous low-speed agitation creates overall circulation in the tank, preventing light components from floating and asphaltenes/modifiers from settling. No stratification, skinning, or bottom sediment after prolonged standing.

  2. Enhance heat transfer and shorten heating time
    Agitation ensures continuous contact between asphalt, tank wall, and thermal oil heating coils, eliminating the temperature gradient of “wall overheating and cold center.” More uniform and faster heating, lower fuel consumption.

  3. Eliminate localized overheating and coking
    Forced circulation suppresses localized hot spots, prevents coking and carbonization on heating surfaces, extends asphalt performance stability, and reduces tank cleaning frequency.

  4. Stabilize spraying accuracy
    Uniform asphalt viscosity is a prerequisite for accurate application rate. Agitation ensures consistent flowability and density of pumped asphalt, bringing actual application rate closer to the set value and reducing transverse and longitudinal spray deviations.

Pneumatic Control Valve Manifold for Synchronous Chip Sealer

Centralized control and air preparation unit for the vehicle’s pneumatic system. It distributes, regulates, and filters the chassis air supply, then delivers it to pneumatic actuators such as asphalt nozzles, aggregate gate cylinders, tank cover lifting, and cleaning/blow-off circuits—enabling centralized switching, individual adjustment, and quick maintenance.

  1. Centralized air supply distribution
    A single main air inlet is distributed through the valve manifold to all pneumatic circuits, avoiding pressure interference from multiple take-off points and ensuring stable air pressure during simultaneous operation.

  2. Independent on/off control for each circuit
    Each circuit is equipped with an independent manual ball valve (yellow handle for clear identification), allowing individual opening or closing. Only required circuits can be opened during operation; a faulty circuit can be isolated without shutting down the entire air supply or stopping maintenance.

  3. Branch pressure regulation and visual pressure monitoring
    Each circuit is fitted with a filter regulator and pressure gauge, allowing separate pressure settings according to actuator requirements (e.g., nozzle atomizing pressure, aggregate gate cylinder thrust, and blow-off pressure). Operators can read pressures directly, preventing cylinder damage from overpressure or incomplete gate opening from insufficient pressure.

  4. Air purification to protect actuators
    Oil-water separator bowls filter moisture, oil mist, and particulate contaminants from compressed air, preventing cylinder bore corrosion, solenoid valve spool sticking, and seal aging—significantly extending pneumatic component life and reducing valve freezing/sticking in winter.

  5. Fast response and high control accuracy
    Pneumatic actuation is better suited to rapid reciprocating “open/close” actions than hydraulics. Nozzle opening/closing and aggregate gate operation respond quickly; combined with solenoid valves, sectional and lane-width control can be achieved for neat spraying edges.

  6. Spare circuits reserved for expansion
    Multiple “SPARE” air ports are provided on the label plate, allowing on-site installation of blow guns, pneumatic tools, air horns, or additional actuators without modifying existing piping.

  7. Clear identification and easy maintenance
    The valve manifold is centrally located on the side of the vehicle at an accessible position, with bilingual (Chinese-English) label plates and one-to-one correspondence between piping routes and functions. Quick-change couplings allow disassembly without special tools, improving on-site troubleshooting efficiency.

Aggregate Hopper Lifting Device for Synchronous Chip Sealer

A hopper lifting actuator consisting of a heavy-duty hydraulic lifting cylinder, hinged pin supports, and a hydraulic control circuit. It raises the fully loaded aggregate hopper to the dump angle for loading, unloading, and hopper cleaning.

  1. Self-dumping hopper lifting
    The hydraulic cylinder pushes the hopper to pivot around the rear hinge point, dumping residual aggregate in one pass without manual clearing. After operation, the hopper can be quickly emptied to prevent residual chips from absorbing moisture, caking, and blocking the aggregate gate.

  2. Multi-stage telescopic design with long stroke and compact structure
    A multi-stage (telescopic) hydraulic cylinder achieves a long effective lifting stroke and large tilt angle within the limited frame installation space, without occupying hopper payload volume or raising the vehicle’s center of gravity.

  3. Heavy-duty lifting capacity
    Cylinder bore and rod diameter are designed for the fully loaded aggregate weight, stably lifting several tonnes to over ten tonnes. All stages extend synchronously, with no creeping or impact during lifting.

  4. Hydraulic drive with adjustable speed and mid-position holding
    Oil is supplied by the chassis hydraulic system and controlled by a directional valve for lifting/lowering speed. A counterbalance valve (hydraulic lock) allows the hopper to hold at any angle without sinking, facilitating inspection and maintenance in the tilted position.

  5. Hinged mounting for rational load distribution
    Pin-connected supports at both ends allow the cylinder body to swing freely with the hopper during lifting, avoiding lateral bending moments, reducing cylinder bore uneven wear and seal eccentric loading, and extending service life.

  6. Easy hopper cleaning and twin-screw distributor maintenance
    When lifted, the hopper bottom is fully exposed for direct washing of the inner walls and inspection of the twin-screw distributor and aggregate gate mechanism. Routine maintenance no longer requires entering the hopper, significantly improving safety.

  7. Safety interlock and mechanical support
    Interlocked with the vehicle’s pneumatic/hydraulic system to restrict vehicle travel during lifting. A mechanical support strut or locking device secures the hopper at the raised position, preventing accidental fall in case of hydraulic pressure loss.

Pneumatic Actuator Array for Aggregate Gates on Synchronous Chip Sealer

The core actuation unit of the aggregate spreading system, consisting of multiple solenoid valves and cylinders. Each channel independently drives one aggregate gate, precisely controlling gate opening and closing per electronic commands to achieve sectional, lane-width, and quantitative chip spreading.

  1. Multi-channel independent control, one valve per gate
    Each solenoid valve independently controls one cylinder and its corresponding gate, with no interference between circuits. If one channel fails, it can be individually shut off or replaced while the remaining circuits continue working—no full shutdown required.

  2. Stepless adjustable spreading width
    By combining gates at different positions, the spreading width can be freely set from 0 to the maximum (typically 3–4 m). Precise avoidance around pavement edges, bridge approaches, and manhole covers reduces manual patching and chip waste.

  3. Precise aggregate spread rate control
    Gate opening duration and opening degree jointly determine the application rate per unit area. Fast solenoid valve response enables millisecond-level timing, and combined with vehicle speed feedback, achieves quantitative spreading at the set kg/m²—avoiding local over-application or bare spots.

  4. Synchronized with asphalt spraying
    Fast pneumatic actuation ensures good synchronization between gate opening/closing and asphalt nozzle opening—meeting the process requirement of “asphalt first, chips immediately following” for consistent seal coat bonding quality.

  5. Corrugated boot dust protection
    Cylinder piston rods are fitted with corrugated dust boots to block chip dust and asphalt mist from entering the cylinder bore, preventing rod scoring and seal failure—significantly extending cylinder life and reducing valve/cylinder sticking.

  6. Quick-change couplings for easy maintenance
    Air lines use quick-change couplings, and solenoid valves use plug-in wiring. A single channel can be replaced in minutes without disassembling the entire valve block. Centralized layout on the vehicle side facilitates routine inspection and troubleshooting.

  7. Integrated with electronic control system
    Solenoid valves are controlled by PLC output signals. Operators can set spreading width, lane combination, and application rate on the touchscreen in the cab or at the rear platform. Parameters can be stored and reused for high consistency on repeated work sections.

  8. Modular expansion
    Valve groups are modularly combined by standard channel counts (typically 16 or 20 channels). Modules can be added or removed according to spreading width requirements, with no need to modify the overall structure for future expansion.

Centralized Control Panel for Synchronous Chip Sealer

The operation and parameter control hub of the entire vehicle. It centralizes all working controls—asphalt spraying, aggregate spreading, tank heating and insulation, hopper lifting, and agitation/circulation—at a single operating position. Parameters are set via touchscreen and actions executed via rotary knobs, supporting both manual and automatic working modes.

  1. Touchscreen parameter setting and real-time monitoring
    The screen allows setting and real-time display of asphalt application rate (kg/m²), aggregate spread rate (kg/m²), spreading width, vehicle speed, asphalt temperature, thermal oil temperature, asphalt pressure, asphalt pump flow, and burner temperature. Operators can monitor the entire vehicle’s working status without leaving the cab, enabling immediate detection of abnormalities.

  2. Individual channel addressing control for nozzles and gates
    Asphalt nozzles are numbered 1–32 and aggregate gates 1–16. They can be opened as a group or individually selected channel by channel. At start-up, finishing, and when avoiding manholes and bridge approaches, specific channels can be precisely shut off for neat joints and no material waste.

  3. Manual/automatic dual mode
    In manual mode, buttons directly actuate functions—suitable for vehicle positioning, test spraying, and troubleshooting. In automatic mode, the system automatically adjusts asphalt pump displacement and gate opening based on vehicle speed feedback to achieve uniform application; the operator only controls speed and direction.

  4. Physical rotary knobs as reliable backup to the touchscreen
    Hopper lifting, left/right circulation, large/small spreading, rear gate opening, lighting, agitation, brake, air horn, rear door, and PTO each have independent rotary knobs with clear bilingual (Chinese-English) position markings (raise/lower/stop, open/close, decrease/increase). If the touchscreen fails or in low-temperature environments, operations can still be completed purely manually—the entire truck will not be stopped by a single screen failure.

  5. Independent adjustment of hopper lifting and rear gate opening
    The hopper lifting knob controls the lifting cylinder with clear raise/lower/stop positions. Rear gate opening can be continuously increased or decreased for fine adjustment of the aggregate drop gap, working in conjunction with gate control to regulate spread rate.

  6. Circulation and agitation control
    Left/right small circulation, large circulation, and agitation switches are independently arranged. Circulation paths can be selected according to tank capacity and asphalt viscosity to ensure uniform temperature and composition within the tank.

  7. Centralized auxiliary and safety operations
    Lighting, air horn, brake, rear door, and PTO power indication are all on the panel. Night-time operation, audible warnings, and power take-off confirmation are no longer scattered—reducing misoperation.

  8. Industrial-grade protective design
    The control box features a sunshade and rain cover. The panel is inclined for comfortable standing operation. Buttons and knobs are designed against accidental touch. Suitable for site dust, sunlight, and rain exposure.

In-Vehicle Camera and Dual-Screen Monitoring System for Synchronous Chip Sealer

A visual assistance system in the cab, consisting of a forward-facing camera and two in-cab displays. It allows the operator to view both the road ahead and the rear spreading operation from the driving position, supporting construction quality monitoring and driving safety recording.

  1. Real-time monitoring of rear spreading operation
    The display receives the rear camera feed, allowing the operator to observe in real time whether the asphalt nozzles are spraying in a normal fan pattern, whether aggregate is spread evenly, and whether there is material blockage, missed spreading, or local bare spots. Issues can be corrected on the spot by adjusting vehicle speed or aggregate gate opening—no need to stop and inspect outside the cab.

  2. Full driving process recording
    The forward-facing camera records the entire driving and construction process. It functions both as a dashcam for accident evidence and responsibility determination, and as a construction image archive for quality traceability and client acceptance demonstration.

  3. Dual-screen division with no mutual obstruction
    The two screens display different images separately (e.g., one for rear spreading, one for hopper/agitation or road ahead), avoiding frequent switching on a single screen and keeping the viewing angle complete during operation. Each screen has an independent bracket with adjustable tilt to suit the driver’s height and seating position, without sunlight glare blocking the view.

  4. Reversing and narrow-section assistance
    Rear-view images assist with reversing, turning around, pulling over, and positioning at the paving start point, reducing collision risks with curbs, guardrails, and workers—especially advantageous at bridge approaches, tunnel portals, and other narrow work areas.

  5. Fewer exits from the cab, improved safety
    Frequent getting on and off to check spreading quality during synchronous seal coating is a common safety hazard. With monitoring images, most judgments can be made from the driving position, significantly reducing personnel exposure to traffic.

  6. Night and low-light operation assistance
    Cameras can image in low-light conditions. With screen brightness adjustment, spreading boundaries and chip coverage remain distinguishable during night work, ensuring night-time quality.

  7. Stable installation, vibration-resistant and durable
    Cameras are mounted on the windshield or dashboard via brackets, using automotive-grade wiring harnesses and vibration-damping structures. They do not loosen or shake during long-term rough operation, ensuring stable images.

Asphalt Filtration and Insulated Piping System for Synchronous Chip Sealer

The conveying and purification unit between the asphalt tank and the nozzles, consisting of filters, insulated piping, valves, and the pump unit. It delivers high-temperature asphalt to each nozzle at stable pressure and in a clean condition, ensuring uniform spraying without blockage or leakage.

  1. Asphalt filtration and purification to prevent nozzle clogging
    The filter housing contains a screen that intercepts coke particles, impurities, and residue in the asphalt before it enters the spraying system. Nozzle orifices are typically only 1–3 mm; a single piece of coke slag can distort the spray fan pattern. The filter screen is the first line of defense for spraying quality.

  2. Quick-opening structure for fast cleaning and maintenance
    The top of the housing uses a quick-opening clamp cover with a handle and clamping bolts. After depressurization, the cover can be opened to remove the screen for cleaning or replacement—no pipe disassembly and no special tools required. Routine maintenance can be completed in about ten minutes, reducing downtime.

  3. Full-circuit insulation to reduce heat loss
    Asphalt piping is wrapped with insulation and covered with aluminum foil to suppress heat dissipation during transport. Once asphalt temperature drops, viscosity rises and flowability deteriorates, causing difficult pumping, poor nozzle atomization, or even pipe blockage. The insulation layer ensures the temperature at the nozzles still meets process requirements.

  4. Zoned valve control for flexible process switching
    Manual valves such as butterfly valves switch asphalt flow among “in-tank circulation — pumping/spraying — drain and pigging — sampling.” Before operation, the circulation loop preheats the piping; after operation, circulation can return residual material in the pipes to the tank, reducing waste and cleaning workload.

  5. Stable pump unit delivery, hydraulically driven
    The asphalt pump is driven by a hydraulic motor, providing stable output pressure and adjustable flow. Linked with vehicle speed, it achieves quantitative application. Hydraulic drive offers stepless speed regulation to suit different asphalt viscosities and application rate requirements.

  6. Flange connections for reliable sealing
    Filters, valves, and piping are connected by flanges with high-temperature-resistant gaskets. Evenly tightened bolts prevent leakage under high temperature and pressure, avoiding burns and contamination caused by asphalt leakage.

  7. Clear safety warnings
    The housing is labeled with warnings such as “Depressurize before opening” and “Beware of burns,” reminding operators not to open the cover under pressure or at high temperature, thereby reducing the risk of burns and asphalt splashing.

  8. Compact layout with accessible maintenance
    The filter, valves, and pump unit are centrally arranged at the rear side of the tank. Valve handwheels face the operating side, allowing screen replacement, valve operation, and pump inspection to be performed on site without crawling under the vehicle or disassembling other components.

Asphalt Pump Assembly for Synchronous Chip Sealer

The power core of the asphalt spraying system, consisting of a gear pump, hydraulic drive, flanged piping, and heat tracing/insulation structure. It continuously, stably, and adjustably delivers high-temperature asphalt from the tank to the spray bar and nozzles, and is the direct execution component for achieving the set application rate.

  1. High-flow, stable pumping
    The external gear pump features a simple structure, high-temperature resistance, and strong contamination tolerance, and can continuously deliver high-temperature asphalt and modified asphalt. Output flow is approximately proportional to rotational speed; at constant speed, flow remains stable, preventing the spray fan pattern from fluctuating.

  2. Hydraulic drive with stepless speed regulation and forward/reverse rotation
    The pump is driven by a hydraulic motor, enabling stepless speed regulation to suit different application rates (kg/m²) and vehicle speeds. The forward/reverse function allows residual material in the piping to be drawn back into the tank after operation, reducing asphalt waste and pipe cleaning workload.

  3. Vehicle speed linkage for quantitative application
    The control system adjusts pump speed in real time based on vehicle speed feedback—faster pumping at higher speed and slower pumping at lower speed—ensuring a constant application rate per unit area and avoiding uneven thickness at start-up and stopping sections.

  4. Heat tracing and insulation to prevent solidification in the pump
    The pump body and inlet/outlet piping are provided with heat tracing/insulation measures to keep the asphalt inside the pump above its flow temperature. Asphalt cooling and solidifying inside the pump can cause difficult start-up, gear seizure, and seal damage; heat tracing is key to ensuring normal operation in low-temperature environments.

  5. Insulated piping to reduce heat loss
    Asphalt delivery piping is wrapped with insulation and aluminum foil to suppress heat dissipation, ensuring the asphalt temperature at the nozzles still meets atomization requirements and reducing heating energy consumption.

  6. Flanged connections for reliable pressure-tight sealing
    The pump body and piping are all connected by flanges with high-temperature-resistant gaskets. Evenly tightened bolts prevent leakage under high temperature and pressure, reducing contamination and burn risks caused by asphalt dripping.

  7. Convenient maintenance with replaceable wear parts
    The pump body is mounted on a checkered steel plate platform with operating space around it. End covers, seals, and gear components can be disassembled and replaced on site without lifting the entire pump body, shortening downtime due to faults.

Electrical Control Unit (Control Cabinet) for Synchronous Chip Sealer

The nerve center of the vehicle’s electrical and automatic control system. It collects signals such as vehicle speed, temperature, pressure, and switch status, processes them through the controller, and outputs commands to drive actuators including the asphalt pump proportional valve, pneumatic solenoid valves, aggregate gate actuators, and burner—converting parameters set by the operator on the touchscreen into actual actions.

  1. Centralized processing and logic control
    The main control module runs the vehicle control program, handling manual/automatic mode switching, application rate closed-loop control, temperature control, lifting interlock, and fault diagnosis—the computing basis for achieving “spray exactly as set.”

  2. Modular structure for easy expansion and maintenance
    The main control module, power module, and expansion modules are plug-in mounted on DIN rails. When adding nozzle channels, installing additional sensors, or upgrading functions, only additional modules and bus connections are required—no need to replace the entire control cabinet.

  3. Centralized terminal wiring with one-to-one circuit correspondence
    All input/output wires are terminated at numbered terminal blocks. Terminal numbers correspond one-to-one with drawings and wire numbers. During on-site troubleshooting, voltage or continuity can be measured by terminal number to quickly locate the specific circuit—no need to disconnect and test wires one by one.

  4. Standardized wiring, vibration-resistant and anti-loosening
    Wire harnesses run in dedicated channels and are secured with cable ties. High-voltage and low-voltage wiring are separated to reduce loosening, abrasion, and interference caused by vibration, suitable for long-term rough operation.

  5. Unified actuation of execution components
    Output modules drive the asphalt pump proportional valve (pump displacement control), pneumatic solenoid valves (aggregate gates and nozzles), burner ignition and temperature control, lighting, and alarms—one cabinet covers all vehicle action control.

  6. Electrical protection and isolation
    Equipped with circuit breakers, fuses, and relay isolation. In case of short circuit, overload, or reverse connection, the fuse protects the module first, preventing a single module failure from causing loss of vehicle control. Relays enable low-voltage control of high-voltage circuits, improving system reliability.

  7. Data interaction with touchscreen
    Communicates with the HMI in the cab and at the rear operating platform, uploading real-time temperature, pressure, flow, and vehicle speed data, and downloading set parameters. Parameter storage and recall are supported for high consistency on repeated work sections.

  8. Protection and maintenance design
    The cabinet uses a metal flip-cover structure, dustproof and waterproof when closed. Opening the cover exposes all modules and terminals. The internal layout is clearly zoned, with modules and terminals separated to avoid interference during maintenance.

Pneumatic Valve Manifold Assembly for Synchronous Chip Sealer

The centralized control and air distribution unit for pneumatic actuators. Multiple solenoid valves are centrally mounted in the control box with unified numbering, and compressed air is distributed through bundled air lines to actuators such as aggregate gate cylinders and nozzle control cylinders, converting electrical control signals into fast, reliable pneumatic actions.

  1. Centralized multi-channel control with one-to-one numbering
    Solenoid valves are numbered and tagged in sequence (1, 2, 3…) and correspond exactly to the electrical control system’s output points and drawings. If a channel fails to actuate, the corresponding solenoid valve and air line can be found directly by number—troubleshooting does not rely on trial and error.

  2. Conversion of electrical signals into pneumatic actions
    The valve receives 24V output signals from the PLC, shifts the spool, and directs compressed air to one side of the cylinder, pushing the piston rod to extend or retract. This achieves aggregate gate opening/closing and nozzle on/off actions, typically with millisecond-level response.

  3. Centralized air supply with consistent pressure
    All solenoid valves are supplied from the same air source through the main valve manifold, ensuring consistent pressure across branches. This avoids uneven pressure caused by multiple separate air take-off points, which can lead to some gates opening fully while others do not.

  4. Bundled air lines and standardized routing
    All white nylon air lines are bundled and secured by number, with clear routing. They are kept away from moving parts and sharp edges to reduce abrasion and air leakage caused by long-term vibration and friction, and to facilitate overall inspection for kinked or crushed lines.

  5. Quick-connect fittings for fast on-site replacement
    Quick-connect fittings are used between air lines, valve bodies, and cylinders, allowing push-pull disassembly and assembly. A single solenoid valve or air line can be replaced in minutes without welding or re-piping, enabling rapid recovery from faults during field operation.

  6. Modular valve manifold for easy expansion and complete replacement
    The valve manifold uses a centralized mounting rack, and modules can be added or removed according to channel count. If the entire group needs replacement, it can be removed and swapped as a whole to shorten downtime. Spare air ports are also available for adding blow-off guns or new actuators.

  7. In-box installation with effective protection
    The valve manifold is placed inside a metal control box, protecting it from chip splatter, dust accumulation, and direct rain exposure, and preventing solenoid coils from impact damage—suitable for harsh site environments.

  8. Coordination with external manual air valve group
    The solenoid valves inside the box handle precise actions for automatic control, while the manual ball valve group on the vehicle side handles main air supply switching, cleaning, lifting, and other operations. The two systems complement each other, allowing manual emergency operation if automatic control fails.

After-sales and service

We provide lifelong tracking service and one year free warranty for all of our products. Meanwhile we provide free training and technical support to guide you repair your product. If need, we will also send original spare parts free of charge by air.

Delivery Time

We do our best to ensure that orders are ready for dispatch within 24 working days (after payment is received)

Delivery areas

Whether you are in a bustling city or a quiet island, our global logistics network can seamlessly reach any sovereign country and region in the world.

Get A Quote

Inquiry Now